A partir de tradutores profissionais, empresas, páginas da web e repositórios de traduções disponíveis gratuitamente
la turbina rotor / stator optimizada energéticamente está concebida de tal manera que pueda aspirar el aire fresco directamente del entorno al acetator por una tubería de aire sin compresora adicional.
the energy-efficient rotor-stator-turbine is designed so that it can suck fresh air into the acetator via an air line directly from the environment without an additional compressor.
Última atualização: 2018-02-13
Frequência de uso: 1
Qualidade:
== normas internacionales ==* iec 60270:2000/bs en 60270:2001 "high-voltage test techniques - partial discharge measurements"* iec 61934:2006 "electrical insulating materials and systems - electrical measurement of pd under short rise time and repetitive voltage impulses"* iec 60664-4:2007 "insulation coordination for equipment within low-voltage systems – part 4: consideration of high-frequency voltage stress"* iec 60034-27:2007 "rotating electrical machines – off-line partial discharge measurements on the stator winding insulation of rotating electrical machines"* ieee std 436™-1991 (r2007) "ieee guide for making corona (partial discharge) measurements on electronics transformers"* ieee 1434–2000 "ieee trial-use guide to the measurement of partial discharges in rotating machinery"* ieee 400-2001 "ieee guide for field testing and evaluation of the insulation of shielded power cable systems"== referencias ==== véase también ==* arborescencia eléctrica== enlaces externos ==* acerca de las descargas parciales* recurso en línea sobre descargas parciales* descargas parciales
==international standards and informative guides==* iec 60270:2000/bs en 60270:2001 "high-voltage test techniques – partial discharge measurements"* iec 61934:2006 "electrical insulating materials and systems - electrical measurement of pd under short rise time and repetitive voltage impulses"* iec 60664-4:2007 "insulation coordination for equipment within low-voltage systems – part 4: consideration of high-frequency voltage stress"* iec 60034-27:2007 "rotating electrical machines – off-line partial discharge measurements on the stator winding insulation of rotating electrical machines"* ieee std 436™-1991 (r2007) "ieee guide for making corona (partial discharge) measurements on electronics transformers"* ieee 1434–2000 "ieee trial-use guide to the measurement of partial discharges in rotating machinery"* ieee 400-2001 "ieee guide for field testing and evaluation of the insulation of shielded power cable systems"==see also==*condition-based maintenance*condition monitoring*dissolved gas analysis*electric generator*electric motor*electric power distribution*electric power transmission*electrical substation*electrical treeing*switchgear*transformer==references====bibliography==* high voltage engineering fundamentals, e.kuffel, w.s.
Última atualização: 2016-03-03
Frequência de uso: 1
Qualidade:
Aviso: contém formatação HTML invisível